1.0 INTRODUCTION
Detcon Model 210A-FB gas detection system consists of 3 major assemblies:
1. The NEMA 4 fiberglass control enclosure.
2. The single channel digital control modules.
3. The remote mount gas sensor assemblies.
The NEMA 4 fiberglass control enclosure is detailed in section 1.0 of the manual, the
control modules in section 2.0 and applicable sensor assemblies in section 3.0.
Detcon Model 210A-FB
Gas Detection System
Operators Instruction Manual
Document #788, September 14, 1999, Revision 1.0
POWER
MODEL 210AFB
HOUSTON
TEXAS
detcon inc.
1 AMP ALARM
DISABLE
HIGH
LOW
FAULT
ALARM
RESET
HOUSTON, TEXAS
MODEL 10A
H
2
S MONITOR
ppm
L
O
C
K
detcon inc.
HIGH
LOW
FAULT
ALARM
RESET
HOUSTON, TEXAS
MODEL 10A
H
2
S MONITOR
ppm
L
O
C
K
detcon inc.
HIGH
LOW
FAULT
ALARM
RESET
HOUSTON, TEXAS
MODEL 10A
H
2
S MONITOR
ppm
L
O
C
K
detcon inc.
Przeglądanie stron 0
1 2 3 4 5 6 7 8

Podsumowanie treści

Strona 1 - Detcon Model 210A-FB

detcon inc.❏ 1.0 INTRODUCTIONDetcon Model 210A-FB gas detection system consists of 3 major assemblies: 1. The NEMA 4 fiberglass control enclosure.

Strona 2 - ❏ 1.3 ALARM DISABLE

❏ 1.1 DESCRIPTIONswitch, an alarm disable switch and a line power fuse.Discreet output terminal strips located on the controllermother board are pro

Strona 3 - ❏ 1.7 POWER SUPPLY

Detcon Model 210A-FB Gas Detection System PG.3Upon completion of all field wiring: Depress the power switch on the controllerassembly front panel.

Strona 4 - ❏ 1.8 WARRANTY

Shipping address: 3200 A-1 Research Forest Dr., The Woodlands, Texas 77381Mailing address: P.O. Box 8067, The Woodlands, Texas 77387-8067 ❏ Phone:

Strona 5 - FAULTHIGHLOW

TED S.TITLEDRN BYFINISHSCALESHEET OFAPPROVED BYDRAWING NUMBERDATESTATUSMATERIALdetcon inc.STOCK #REV #210A-FB SCHEMATIC/WIRING DIAGRAM73

Strona 6 - MODEL 210AFB

TED S.TITLEDRN BYFINISHSCALESHEET OFAPPROVED BYDRAWING NUMBERDATESTATUSMATERIALdetcon inc.STOCK #REV #210A-FB CONTROLLER TERMINALS0786.2

Strona 7 - 8.75" 8.75"

TITLEDRN BYFINISHSCALESHEET OFAPPROVED BYDRAWING NUMBERDATESTATUSMATERIALdetcon inc.STOCK #REV #TED S.210A-FB ENCLOSURE DIMENSIONS MOUNT

Strona 8 - MULTIPLE ALARM RELAY CIRCUIT

TED S.TITLEDRN BYFINISHSCALESHEET OFAPPROVED BYDRAWING NUMBERDATESTATUSMATERIALdetcon inc.STOCK #REV #MULTIPLE ALARM RELAY CIRCUIT377.01

Komentarze do niniejszej Instrukcji

Brak uwag